WebAug 5, 2024 · Anything that can form a barrier on the river while still letting water pass through could create a potentially deadly trap known as a strainer. Here are some … Drip Legsare installed in steam mains to serve the following purposes: 1. Drip Legsare used for removing entrained moisture from the steam transmission and distribution lines to ensure high-quality steam for use in various plant applications, while also preventing damaging and dangerous water hammer. 2. … See more Drip Legs are vertical piping pockets installed in steam piping to collect condensate. Installing drip legs in the proper location serves the purpose of a successful, water-hammer-free, system start-up. See more Due to heat loss and system start-up energy consumption, condensate is formed inside the steam pipes. For proper working of the steam system, this condensate must be drained by installing drip legs in main lines … See more Because condensate drainage from steam systems is dependent upon gravity, the drip leg (Fig. 1) diameter is critical for optimum removal – … See more
Steam Mains and Drainage Spirax Sarco
WebFeb 23, 2024 · Drip legs If you don’t have a refrigerated, membrane, or desiccant dryer, then you need to put drip legs in your pipe. Compressors squeeze a lot of water out of the air. A filter will only get out some of it. If you don’t have a … WebSep 19, 2024 · However, if it encounters a strainer on its path through the system, then it can quickly clog the strainer, starve the pump, and cause severe issues with cavitation. If … chip shop withernsea
Cooling leg for a thermostatic trap questions - Heating Help: The …
WebA blowdown valve can also be fitted to cap ‘D’ to facilitate regular cleaning. Strainers can however, be a source of wet steam as previously mentioned. To avoid this situation, … WebPressure Loss: Basket strainers exhibit less pressure loss as compared to Y-strainers. That’s why when there is doubt a basket strainer can easily be installed. It will cost more but serve all the purposes. Note that, purchasing a spare pipe strainer is always a good engineering practice to avoid unnecessary delays in cleaning and installation for line operation. Webdrip. 4.install legs of strainers in horizontal position , vertical acceptable if needed to minimize condensate holding. strainer mesh=20 or higher. 5.use a minimum of two 90 degree bends between check valve and isolation valve on condensate main, to allow thermal growth/expansion between steam and condensate return pipes. chip shop wishaw